echo.models.thermal.simple_heatpump module

class echo.models.thermal.simple_heatpump.SimpleHeatPump(uid: str = NOTHING, node_name: str = NOTHING, ports: dict[str, Port] = NOTHING, objective: en.numeric_expr.NumericExpression | float = 0, max_cooling_capacity: float | None = None, max_heating_capacity: float | None = None, heating_cop_time_series: dict | None = None, cooling_cop_time_series: dict | None = None, heating_cop_time_series_ref: str | None = None, cooling_cop_time_series_ref: str | None = None, cooling_cop_constant: float = 1, heating_cop_constant: float = 1, electrical_input_port_ref: str = 'input', thermal_output_port_ref: str = 'output')

Bases: Node

A simple heat pump model that uses predefined COP (coefficient of performance) values for heating and cooling.

SimpleHeatPump has one input electrical port, and one bidirectional thermal port. In this configuration the heatpump can do heating or cooling, but not both simultaneously.

The conversion of input electrical energy to heating or cooling output depends on provided coefficients of performance (COP) time series data.

add_node_to_model(model: EchoConcreteModel, profile: DataFrame) → None

Add this node to a concrete model.

Parameters:
  • model – The concrete model to add the node to.

  • profile – The data associated with this node.

apply_node_constraints(model: EchoConcreteModel) → None

Apply constraints associated with this node to a concrete model.

Intended to be overridden in subclasses.

Define constraints as functions that returns a Constraint, EqualityExpression or InequalityExpression.

Define a subfunction of the form detailed in the example below, then apply with setattr. For example:

def apply_node_constraints(self, model: EchoConcreteModel) -> None:
def tellegen_node_rule(model: EchoConcreteModel, p: int, t:int) -> EqualityExpression:

a = 0 for port in node_ports.values():

a += getattr(model, port.port_name)[p, t]

return a == 0

node_ports = self.ports con_name = “reliability_con_” + self.node_name setattr(model, con_name, en.Constraint(model.Expansion, model.Time, rule=tellegen_node_rule))

Parameters:

model – The model to add the constraints to.

Returns:

None

property cooling_cop: str
cooling_cop_constant: float
cooling_cop_time_series: dict | None
cooling_cop_time_series_ref: str | None
create_ports() → None
electrical_input_port_ref: str
property heating_cop: str
heating_cop_constant: float
heating_cop_time_series: dict | None
heating_cop_time_series_ref: str | None
max_cooling_capacity: float | None
max_heating_capacity: float | None
property power_to_cool: str
property power_to_heat: str
set_ports(electrical_input_port: FlexSink, thermal_output_port: FlexPort) → None
thermal_output_port_ref: str
update(heating_cop_time_series: dict[float, float], cooling_cop_time_series: dict[float, float]) → None