echo.models.thermal.parameterised_heatpump module
- class echo.models.thermal.parameterised_heatpump.ParameterisedHeatPump(uid: str = NOTHING, node_name: str = NOTHING, ports: dict[str, Port] = NOTHING, objective: en.numeric_expr.NumericExpression | float = 0, nominal_heating_cop: float = 1, nominal_cooling_cop: float = 1, partial_load_cop_heating: dict = {0: 0, 0.25: 0.8, 0.5: 0.9, 0.75: 1, 1: 0.85}, partial_load_cop_cooling: dict = {0: 0, 0.25: 0.8, 0.5: 0.9, 0.75: 1, 1: 0.85}, temperature_dependent_cop_heating: dict = {-10: 0.4, 0: 0.6, 10: 0.7, 20: 0.9, 30: 1, 45: 1}, temperature_dependent_cop_cooling: dict = {0: 0.7, 10: 1, 20: 0.5, 30: 0.35, 45: 0.2}, ambient_temperature_dict: dict = NOTHING, ambient_temperature_ref: str | None = None, constant_ambient_temperature: float = 10, heat_intake_rejection_port: bool = False, heat_intake_rejection_coefficient: float = 1, input_points_cooling: dict | None = None, output_points_cooling: dict | None = None, input_points_heating: dict | None = None, output_points_heating: dict | None = None, electrical_input_port_ref: str = 'input', thermal_output_port_ref: str = 'output', heat_intake_rejection_port_ref: str = 'heat_intake_rejection', *, max_heating_capacity: float, max_cooling_capacity: float)
Bases:
NodeA Parameterised heat pump model.
This model is different to simple heatpump model in that it uses piecewise linear partial load COP factor (coefficient of performance) and piecewise linear temperature COP factor to calculate actual values for heating and cooling at each step.
HeatPumpTwoPipe has one input electrical port and one bidirectional thermal port. The heat pump can do heating or cooling, but not both simultaneously.
The conversion of input electrical energy to heating or cooling output depends on calculated coefficients of performance (COP) at each time step.
- add_node_to_model(model: EchoConcreteModel, profile: DataFrame) None
Set up variables and parameters associated with the node
- ambient_temperature_dict: dict
- ambient_temperature_ref: str | None
- apply_node_constraints(model: EchoConcreteModel) None
Set up constraints associated with the node
- constant_ambient_temperature: float
- create_ports() None
- electrical_input_port_ref: str
- heat_intake_rejection_coefficient: float
- heat_intake_rejection_port: bool
- heat_intake_rejection_port_ref: str
- input_points_cooling: dict | None
- input_points_heating: dict | None
- max_cooling_capacity: float
- max_heating_capacity: float
- nominal_cooling_cop: float
- nominal_heating_cop: float
- output_points_cooling: dict | None
- output_points_heating: dict | None
- partial_load_cop_cooling: dict
- partial_load_cop_heating: dict
- property power_to_cool: str
- property power_to_heat: str
- set_ports(electrical_input_port: FlexSink, thermal_output_port: FlexPort, heat_intake_rejection_port: FlexPort | None = None) None
- property temperature_cop_cooling_param: str
- property temperature_cop_heating_param: str
- temperature_dependent_cop_cooling: dict
- temperature_dependent_cop_heating: dict
- thermal_output_port_ref: str
- update(ambient_temperature_dict: dict[float, float]) None